Post Buying Request
TREF2 125A 3p, Thermal Adjustable, Compact Size, Earth Leakage Protection Switch
TREF2 125A 3p, Thermal Adjustable, Compact Size, Earth Leakage Protection Switch
TREF2 125A 3p, Thermal Adjustable, Compact Size, Earth Leakage Protection Switch
TREF2 125A 3p, Thermal Adjustable, Compact Size, Earth Leakage Protection Switch
TREF2 125A 3p, Thermal Adjustable, Compact Size, Earth Leakage Protection Switch
TREF2 125A 3p, Thermal Adjustable, Compact Size, Earth Leakage Protection Switch

TREF2 125A 3p, Thermal Adjustable, Compact Size, Earth Leakage Protection Switch

Member Details

ZHEJIANG QIANNA ELECTRIC CO.,LTD.

China

Manufacturer

  • Product Details
  • Company Profile

TRE series circuit breaker and auxiliaries comply with the following international standard: 1.IEC/EN 60947-1 Low-voltage switchgear and controlgear-part 1: General rules; 2.IEC/EN 60947-2 Low-voltage switchgear and controlgear-part 2: Circuit breakers; TRE series ELCB(Standard use environment for TRE series ELCB) 1. Ambient temperature: Within the range of -5oC--+40oC(However, the average for the duration of 24 hours must not exceed 35oC); 2. Altitude: 2000m or less 3. Installation class: III 4. The magnetic field near the instalation site should not be more than five times the earth magnetic field in any direction. 5. Pollution: II Classification: According to the poles: 2-poles, 3-poles, 4-poles According to the breaking capacity: S-type, H-type According to the rated current: Fix type, Adjustable type(08In-1.0In) According to the trip action time: Fix type, Adjustable type(0.1s/0.3s/0.5s) According to the rated residual current: Fix type, Adjustable(30mA/100mA/300mA/500mA)

TRE series ELCB

Standard:
TRE series circuit breaker and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;

TRE series ELCB(Standard use environment for TRE series ELCB)
1. Ambient temperature: Within the range of -5oC--+40oC(However, the average for the duration of 24 hours must not exceed 35oC);
2. Altitude: 2000m or less
3. Installation class: III
4. The magnetic field near the instalation site should not be more than five times the earth magnetic field in any direction.
5. Pollution: II

Classification:
According to the poles:                                          2-poles, 3-poles, 4-poles
According to the breaking capacity:                       S-type, H-type
According to the rated current:                               Fix type, Adjustable type(08In-1.0In)
According to the trip action time:                            Fix type, Adjustable type(0.1s/0.3s/0.5s)
According to the rated residual current:                 Fix type, Adjustable(30mA/100mA/300mA/500mA)

Technical data table:

Ampere frame sizeTREF2(125A)
Breaking capacity codeSH
Product code and poles2P3P4P2P3P4P
TREF2-S2TREF2-S2TREF2-S2TREF2-H2TRMF2-H3TRMF2-H4
Protective functionOver load & Short circuit & Ground fault
Rated current, In(A)15, 20, 30, 40, 50, 60, 75, 80, 100, 125
Rated residual currentOperating, IΔn(mA)30, 50, 100, 200, 300, 500
Non-operating, IΔno(mA)15, 25, 50, 100, 150, 250
Adjustable partRated current setting(0.8In-1.0In)
Lockup device for operating handle--
Residual current, IΔn30mA/100mA/300mA/500mA
Trip action time0.1s/0.3s/0.5s
Rated operational voltage, Ue(V), AC 50/60 Hz240/415
Rated insulation voltage, Ui(V)1000
Rated impulse withstand voltage, Uimp(kV)8
Residual current off-time at IΔn ,Sec (s)0.1
StandardConformity with IEC/EN 60947-2
Rated frequency(Hz)50/60
Rated short-circuit breaking capacity, Icu(kA)
AC240V35
50
415V18
35
Ics=% * Icu100%
Mechanical life(circle)8500
Electrical life(circle)1500
Dimension:
Length*Width*Height
2-poles130*50*60
3-poles130*75*60
4-poles130*100*60


Built-in accessory:
TRE Built in accessory.png

Built-out accessory:
TRE Built out accessory.png


Company show:

工厂1.jpg工厂2.jpg工厂3.jpg工厂4.jpg
Exhibition:

展会1.jpg展会2.jpg展会3.jpg展会4.jpg


Send Inquiry to This Supplier

  • Title
  • From*
  • toBruce.lee
  • Message*
  • Minimum Order Quantity*
  • Unit
  • Verification Code*

ok
x

Confirm
Cancel
x
Sign into your account
Member ID or Email
Join Free