Post Buying Request
TRM2-50 2P Frame.50 Mini Size Moulded Case Circuit Breaker with Bimetal Design
TRM2-50 2P Frame.50 Mini Size Moulded Case Circuit Breaker with Bimetal Design
TRM2-50 2P Frame.50 Mini Size Moulded Case Circuit Breaker with Bimetal Design
TRM2-50 2P Frame.50 Mini Size Moulded Case Circuit Breaker with Bimetal Design
TRM2-50 2P Frame.50 Mini Size Moulded Case Circuit Breaker with Bimetal Design
TRM2-50 2P Frame.50 Mini Size Moulded Case Circuit Breaker with Bimetal Design

TRM2-50 2P Frame.50 Mini Size Moulded Case Circuit Breaker with Bimetal Design

Member Details

ZHEJIANG QIANNA ELECTRIC CO.,LTD.

China

Manufacturer

  • Product Details
  • Company Profile

TRM series circuit breaker and auxiliaries comply with the following international standard: 1.IEC/EN 60947-1 Low-voltage switchgear and controlgear-part 1: General rules; 2.IEC/EN 60947-2 Low-voltage switchgear and controlgear-part 2: Circuit breakers; TRM series MCCB(Standard use environment for TRM series MCCB) 1. Ambient temperature: Within the range of -5oC--+55oC(However, when the temperature exceed 40oC,it should be considered to reduce the capacity to use); 2. Relative humidity: Within the range of 45%--85%; 3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered); 4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist; Classification: According to the poles: 2-poles, 3-poles According to the rated current: Fix type

TRM2-50 series mini size MCCB

Standard:
TRM series circuit breaker and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;

TRM series MCCB(Standard use environment for TRM series MCCB)
1. Ambient temperature: Within the range of -5oC--+55oC(However, when the temperature exceed 40oC,it should be considered to reduce the capacity to use);
2. Relative humidity: Within the range of 45%--85%;
3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered);
4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist;

Classification:
According to the poles:                                          2-poles, 3-poles
According to the rated current:                               Fix type

Technical data table:

Model (AF)50AF100AF

Product type
TRM2-50/2TRM2-50/3TRM2-100/2TRM2-100/3

Number of poles
2323

Rated current (A)
In5, 1015, 20, 30, 40, 505, 1015, 20, 30, 40, 5063, 80, 10063, 80, 100

Rated voltage(V)
Ue220/415220/415220/415220/415

Rated Insulated voltage (V),  50/60Hz
Ui500500500500

Rated impulse voltage(kV)
Uimp6666

Ultimate breaking capability(kA)
GB 14048.2, IEC/EN 60947-2
Icu220V415V220V415V220V415V220V415V220V415V
52.510552.5105105
lcs=%×lcu75%75%75%75%75%75%

Dimensions (mm)

downLoadImg.jpg

a50755075
b98989898
c60606060
d80808080
Weight (kg)0.310.410.310.41


Company show:

工厂1.jpg工厂2.jpg工厂3.jpg工厂4.jpg
Exhibition:

展会1.jpg展会2.jpg展会3.jpg展会4.jpg


Send Inquiry to This Supplier

  • Title
  • From*
  • toBruce.lee
  • Message*
  • Minimum Order Quantity*
  • Unit
  • Verification Code*

ok
x

Confirm
Cancel
x
Sign into your account
Member ID or Email
Join Free