TRMF4 250A 3P 200A 250A, LS Design Following IEC60947-2, MCCB
TRMF4 250A 3P 200A 250A, LS Design Following IEC60947-2, MCCB
TRMF4 250A 3P 200A 250A, LS Design Following IEC60947-2, MCCB
TRMF4 250A 3P 200A 250A, LS Design Following IEC60947-2, MCCB
TRMF4 250A 3P 200A 250A, LS Design Following IEC60947-2, MCCB
TRMF4 250A 3P 200A 250A, LS Design Following IEC60947-2, MCCB

TRMF4 250A 3P 200A 250A, LS Design Following IEC60947-2, MCCB

Member Details

ZHEJIANG QIANNA ELECTRIC CO.,LTD.

China

Manufacturer

  • Product Details
  • Company Profile

TRM series circuit breaker and auxiliaries comply with the following international standard: 1.IEC/EN 60947-1 Low-voltage switchgear and controlgear-part 1: General rules; 2.IEC/EN 60947-2 Low-voltage switchgear and controlgear-part 2: Circuit breakers; TRM series MCCB(Standard use environment for TRM series MCCB) 1. Ambient temperature: Within the range of -5oC--+55oC(However, when the temperature exceed 40oC,it should be considered to reduce the capacity to use); 2. Relative humidity: Within the range of 45%--85%; 3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered); 4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist; Classification: According to the poles: 1-pole, 3-poles, 4-poles According to the breaking capacity: S-type, H-type According to the rated current: Fix type, Adjustable type(08In-1.0In)

TRM series MCCB

Standard:
TRM series circuit breaker and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;

TRM series MCCB(Standard use environment for TRM series MCCB)
1. Ambient temperature: Within the range of -5oC--+55oC(However, when the temperature exceed 40oC,it should be considered to reduce the capacity to use);
2. Relative humidity: Within the range of 45%--85%;
3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered);
4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist;

Classification:
According to the poles:                                          1-pole, 3-poles, 4-poles
According to the breaking capacity:                       S-type, H-type
According to the rated current:                               Fix type, Adjustable type(08In-1.0In)


Technical data table:

Ampere frame sizeTRMF4(250A)
Breaking capacity codeSH
Product code and poles1P3P4P1P3P4P
TRMF4-S1TRMF4-S3TRMF4-S4TRMF4-H1TRMF4-H3TRMF4-H4
Rated current, In(A)100, 125, 160, 180, 200, 225, 250
Adjustable partRated current setting(0.8In-1.0In)χχ
Lockup device for operating handleχχ
Rated operational voltage, Ue(V), AC 50/60 Hz240/415
Rated insulation voltage, Ui(V)1000
Rated impulse withstand voltage, Uimp(kV)8
StandardConformity with IEC/EN 60947-2
Rated frequency(Hz)50/60
Rated short-circuit breaking capacity, Icu(kA)
AC240V25503665
415V-37-50
Ics=% * Icu50%100%50%100%
Mechanical life(circle)7000
Electrical life(circle)1000
Dimension:
Length*Width*Height
1-pole150*38*60
2-poles-
3-poles165*105*60
4-poles130*140*60


Built-in accessory:

TRE Built in accessory.png

Built-out accessory:
TRE Built out accessory.png

Company show:

工厂1.jpg工厂2.jpg工厂3.jpg工厂4.jpg
Exhibition:

展会1.jpg展会2.jpg展会3.jpg展会4.jpg


Send Inquiry to This Supplier

  • Title
  • From*
  • toBruce.lee
  • Message*
  • Minimum Order Quantity*
  • Unit
  • Verification Code*

ok
x

Confirm
Cancel
x
Sign into your account
Member ID or Email
Join Free