Post Buying Request
TRMF4 250A Single Phase Moulded Case Circuit Breaker, LS Design MCCB
TRMF4 250A Single Phase Moulded Case Circuit Breaker, LS Design MCCB
TRMF4 250A Single Phase Moulded Case Circuit Breaker, LS Design MCCB
TRMF4 250A Single Phase Moulded Case Circuit Breaker, LS Design MCCB
TRMF4 250A Single Phase Moulded Case Circuit Breaker, LS Design MCCB
TRMF4 250A Single Phase Moulded Case Circuit Breaker, LS Design MCCB

TRMF4 250A Single Phase Moulded Case Circuit Breaker, LS Design MCCB

Member Details

ZHEJIANG QIANNA ELECTRIC CO.,LTD.

China

Manufacturer

  • Product Details
  • Company Profile

TRM series circuit breaker and auxiliaries comply with the following international standard: 1.IEC/EN 60947-1 Low-voltage switchgear and controlgear-part 1: General rules; 2.IEC/EN 60947-2 Low-voltage switchgear and controlgear-part 2: Circuit breakers; TRM series MCCB(Standard use environment for TRM series MCCB) 1. Ambient temperature: Within the range of -5oC--+55oC(However, when the temperature exceed 40oC,it should be considered to reduce the capacity to use); 2. Relative humidity: Within the range of 45%--85%; 3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered); 4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist; Classification: According to the poles: 1-pole, 3-poles, 4-poles According to the breaking capacity: S-type, H-type According to the rated current: Fix type, Adjustable type(08In-1.0In)

TRM series MCCB

Standard:
TRM series circuit breaker and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;

TRM series MCCB(Standard use environment for TRM series MCCB)
1. Ambient temperature: Within the range of -5oC--+55oC(However, when the temperature exceed 40oC,it should be considered to reduce the capacity to use);
2. Relative humidity: Within the range of 45%--85%;
3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered);
4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist;

Classification:
According to the poles:                                          1-pole, 3-poles, 4-poles
According to the breaking capacity:                       S-type, H-type
According to the rated current:                               Fix type, Adjustable type(08In-1.0In)


Technical data table:

Ampere frame sizeTRMF4(250A)
Breaking capacity codeSH
Product code and poles1P3P4P1P3P4P
TRMF4-S1TRMF4-S3TRMF4-S4TRMF4-H1TRMF4-H3TRMF4-H4
Rated current, In(A)100, 125, 160, 180, 200, 225, 250
Adjustable partRated current setting(0.8In-1.0In)χχ
Lockup device for operating handleχχ
Rated operational voltage, Ue(V), AC 50/60 Hz240/415
Rated insulation voltage, Ui(V)1000
Rated impulse withstand voltage, Uimp(kV)8
StandardConformity with IEC/EN 60947-2
Rated frequency(Hz)50/60
Rated short-circuit breaking capacity, Icu(kA)
AC240V25503665
415V-37-50
Ics=% * Icu50%100%50%100%
Mechanical life(circle)7000
Electrical life(circle)1000
Dimension:
Length*Width*Height
1-pole150*38*60
2-poles-
3-poles165*105*60
4-poles130*140*60

Built-in accessory:

TRE Built in accessory.png

Built-out accessory:
TRE Built out accessory.png

Company show:

工厂1.jpg工厂2.jpg工厂3.jpg工厂4.jpg
Exhibition:

展会1.jpg展会2.jpg展会3.jpg展会4.jpg


Send Inquiry to This Supplier

  • Title
  • From*
  • toBruce.lee
  • Message*
  • Minimum Order Quantity*
  • Unit
  • Verification Code*

ok
x

Confirm
Cancel
x
Sign into your account
Member ID or Email
Join Free