Post Buying Request
CNS Moulded Case Circuit Breaker
CNS Moulded Case Circuit Breaker
CNS Moulded Case Circuit Breaker
CNS Moulded Case Circuit Breaker
CNS Moulded Case Circuit Breaker
CNS Moulded Case Circuit Breaker

CNS Moulded Case Circuit Breaker

  • Product Details
  • Company Profile

With 30 years experience, we produce quality MCCB with moderate price. Looking for dealer, wholesaler and other type of clients for further cooperation.

Functions and characteristics

Item No.CNS  800-1600
Number of poles3P, 4P
ControlManualwith toggle
with direct or extended rotary handle
ConnectionsFixedfront connections
Plug-infront connections/rear connections
Electrical characteristics as per IEC60947 and EN60947-2
Rated current(A) InIn800, 1000, 1250, 1600
Rated insulation voltage(V)Ui800
Rated impulse withstand voltage(kV)Uimp8
Rated operational voltage(V)UeAC 50/60Hz,690
Breaking capacity levels
                                      N            H
Utilization categoryAC220/240V                        85          85

380/415V                        50          70
440V                               50          65
500/525V                        40          50
660/690V                        30          42
Operation performanceMechanical10000
Electrical 440V5000
Protection                                                                                          Chart C-1
Overload protectionlong-time delayIr (In x......)
Short-circuit protectionshort-time delayIsd (Ir x......)
InstantaneousIi (In x......)
Indication and control auxiliaries
Auxiliary switch
MX Shunt coil
MN under-voltage coil

Protection

Chart C-1

Protection thresholds and delays are set using the adjustment dials.
Offer standard long time delay setting module.

overload protection

True rms long-time protection.
Thermal memory: thermal image before and after tripping.

Short-circuit protection

Short-time(rms) and instantaneous protection.
Selection of l't type(ON or OFF)for short-time delay.

Neutral protection

On 3-pole circuit breakers, neutral protection is not possible.
On 4-pole circuit breakers, neutral protection may be set using a three-position switch: neutral unprotected (4P 3d), neutral protection at 0.5lr (4P 3d +N/2) or neutralprotection at lr (4P 4d).

lndications

Overload indication by alarm LED on the front; the LED goes on when the current exceeds the long-time trip threshold.

Test

A mini test kit or a portable test kit may be connected to the test connector on the front to check circuit-breaker operation after installing the trip unit or accessories.

1.long-time threshold and trpping delay,2.overload alarm(LED),3.short-time pick-up and tripping delay,4.instantaneous pick-up,5.fixing screw for long-time rating plug,6.test connector

Micrologic name codes