Earth-leakage Vigi Add-on Protection Module For CNSX
Earth-leakage Vigi Add-on Protection Module For CNSX
Earth-leakage Vigi Add-on Protection Module For CNSX
Earth-leakage Vigi Add-on Protection Module For CNSX
Earth-leakage Vigi Add-on Protection Module For CNSX
Earth-leakage Vigi Add-on Protection Module For CNSX

Earth-leakage Vigi Add-on Protection Module For CNSX

  • Product Details
  • Company Profile

With 30 years experience, we produce quality product with moderate price. Looking for dealer, wholesaler and other type of clients for further cooperation.

CNSX Vigi add-on

Addition of the Vigi add-on does not modify circuit-breaker characteristics:

  • compliance with standards

  • degree of protection, class II front-face insulation

  • positive contact indication

  • electrical characteristics

  • trip-unit characteristics

  • installation and connection modes

  • indication, measurement and control auxiliaries

  • installation and connection accessories.

PictureRated VoltageModelDimension(mm)Weight(kg)
Earth-leakage Vigi Add-on Protection Module For CNSX220-440V
440-550V
CNSX、CNSV、CNS
100-250A 3P
105*236*862.5
CNSX、CNSV、CNS、CEZC
400-630A  3P
135*355*1108.8
Earth-leakage Vigi Add-on Protection Module For CNSXCNSX、CNSV、CNS
100-250A 4P
140*236*863.2
CNSX、CNSV、CNS、CEZC
400-630A  4P
180*355*11010.8

Remote indications

Vigi add-on may be equipped with an auxiliary contact (SDV) to remotely signal tripping due to an earth fault.

Use of 4-pole Vigi add-on with a 3-pole CNSX

In a 3-phase installation with an uninterrupted neutral, an accessory makes it possible to use a 4-pole Vigi add-on with connection of the neutral cable.

Power supply

Vigi add-on are self-powered internally by the distribution-system voltage and therefore do not require any external source. They continue to function even when supplied by only two phases.

Vigi add-on selection
TypeVigi MEVigi MHVigi MB
Number of poles3,43,43,4
CNSX 100×
CNSX 160×
CNSX 250××
CNSX 400××
CNSX 630××

 A:Sensitivity setting B:Time-delay setting (for selective earth-leakage protection). C:Lead-seal fixture for controlled access to settings. D:Test button simulating an earth-fault for regular checks on the tripping function E:Reset button (reset required after earth-fault tripping). F:Rating plate G Housing for SDV auxiliary contact.

A Sensitivity setting
B Time-delay setting (for selective earth-leakage protection).
C Lead-seal fixture for controlled access to settings.
D Test button simulating an earth-fault for regular checks on the tripping function
E Reset button (reset required after earth-fault tripping).
F Rating plate
G Housing for SDV auxiliary contact.

Protection characteristics
Sensitivityfixedadjustableadjustable
In (A)0.30.03-0.3-1-3-100.3-1-3-10-30
Time delayfixedadjustableadjustable
Intentional delay
(ms)
<400-60-150-3100-60-150-310
Max. break time
(ms)
<40<40<140<300<800<40<140<300<800
Rated voltage
V AC 50/60 Hz
200...440200...440-440...550200...440-440...550

Vigi 3P add-on may also be used on 3P circuit breakers used for two-phase protection.
If the sensitivity is set to 30 mA, there is no time delay, whatever the time-delay setting.

Operating safety

The Vigi add-on is a user safety device. It must be tested at regular intervals (every 6 months) via test button.