Technical Data
1.Rating

Model

Utilization category

UI(V)

Ue(V)

Conventional heating current

Ie(A)

Controlled power(KW)

CT-20

AC-1 AC-7a

500

230

20

20

4

CT-20

AC-7b

500

230

20

9

1.2

CT-40

AC-1 AC-7a

500

400

40

40

40

CT-63

AC-1 AC-7a

500

400

63

63

40

2.Making and breaking capacity

Model

Utilization category

Making and breaking conditions

Electrification

Interval time(s)

Operating cycle

Ic/Ie

Ur/Ue

COS?

time(s)

times

CT-20

AC-1 AC-7a

1.5

1.05

0.8

0.05

10

50

CT-20

AC-7b

8

1.05

0.45

0.05

10

50

CT-63

AC-1 AC-7a

1.5

1.05

0.8

0.05

10

50

3.Conventional heating current under different ambient temperature

Rated current

40℃

50℃

60℃

70℃

Ie=20A

20A

18A

16A

14A

Ie=40A

40A

38A

36A

32A

Ie=63A

63A

57A

50A

46A