Post Buying Request
CQB5aL-63 4.5kA Residual Current Operated Circuit Breaker with Over-current Protection
CQB5aL-63 4.5kA Residual Current Operated Circuit Breaker with Over-current Protection

CQB5aL-63 4.5kA Residual Current Operated Circuit Breaker with Over-current Protection

Member Details

Zhejiang Chuangqi Electric Co., Ltd.

Wenzhou,Zhejiang,China

Manufacturer

  • Product Details
  • Company Profile

·Overload protection ·Short circuit protection ·Protect people against indirect contacts and additional protection against direct contacts. ·Protect installations against fire hazard due to insulation faults. ·High-quality residual current device ·Wide variety of rated tripping currents Suitable for industrial, commercial, high-rise and civil residences circuit protection.


1  Overview and applications

·Overload protection

·Short circuit protection

·Protect people against indirect contacts and additional protection against direct contacts.

·Protect installations against fire hazard due to insulation faults.

·High-quality residual current device

·Wide variety of rated tripping currents

Suitable for industrial, commercial, high-rise and civil residences circuit protection.


 

2. Type designation

Sinoart enterprise content manager system | Sinoart CMS


3 Technical data

Specifications                                  
Rated voltage (V) :230V~/400~
Rated current (A) 10、16、20、25、32、40、50、63
Rated sensitivity lrn (mA)30、50、100
Rated residual non-operating current0.5 lrn
Poles 1P+N、2P、3P+N、4P
Rated breaking capacity  lcu(A)4500
Rated residual making and breaking capacity lr m2000A
Tripping characteristic 
 
Table 2
Mechanical &Electrical lifeMechanical ≥ 4000 ;Electrical≥ 2000
Pollution degree2
Protection classIP20
Overvoltage category 
StandardsIEC61009-1、GB/T16917.1
Compliant certificationCCC

 

Table  2  Tripping characteristics

Rated current(A)   Test current  Initial status    Tripping time          Expected result          Remarks
≤631.13InColdt≤1hNon-tripping
≤631.45InFollowing previous test  t<1htrippingCurrent  smoothly rises to specified value in 5s
≤632.55InCold1s<t<60s(In≤32A)
1s<t<120s(In>32A)
tripping
≤633InColdt≤0.1sNon-tripping
5Int<0.1stripping
5Int≤0.1sNon-tripping
10Int<0.1stripping
10Int≤0.1sNon-tripping
20Int<0.1stripping

Note: The status "cold " means that the test is carried out at a reference calibration temperature without load before the test.


4  Order Specifications
·When ordering circuit breakers, the following points should be specified:

 A) Product models, such as CQB5aL-63;

 B) Poles of circuit breakers, such as (1P+N);

 C) Rated current of circuit breakers, such as 16A、20A、25A;

 D) Rated residual operating current, such as 30mA;

 E) Order quantity, such as 100 pcs

·Purchase order template

 CQB5aL-63  1P+N  C/16A  30mA  100pcs
 
5 Conductor requirements and cross-sectional area

Rated current (A)Nominal cross-sectional area(mm2)
≤101.5
16~202.5
254
326
40~5010
6316

6.Dimensions and installation sizes (mm) 

 

Sinoart enterprise content manager system | Sinoart CMS

 

 

Sinoart enterprise content manager system | Sinoart CMS


Send Inquiry to This Supplier

  • Title
  • From*
  • toYuanzhao Xu
  • Message*
  • Minimum Order Quantity*
  • Unit
  • Verification Code*

ok
x

Confirm
Cancel
x
Sign into your account
Member ID or Email
Join Free