Post Buying Request
LEL5 (Y30) 1kA Residual Current Circuit Breaker
LEL5 (Y30) 1kA Residual Current Circuit Breaker

LEL5 (Y30) 1kA Residual Current Circuit Breaker

Member Details

Zhejiang Chuangqi Electric Co., Ltd.

Wenzhou,Zhejiang,China

Manufacturer

  • Product Details
  • Company Profile

- Control electric circuits. - Protect people against indirect contacts and additional protection against direct contacts. - Protect installations against fire hazard due to insulation faults. - Single phase and three phase applications(220V/380V) - Wide variety of rated tripping currents

  1. 1 Application

Residual current circuit breakers are used in housing ,tertiary sector and industry.

-  Control electric circuits.

- Protect people against indirect contacts and additional protection against direct contacts.

-  Protect installations against fire hazard due to insulation faults.

-  Single phase and three phase applications(220V/380V)

-  Wide variety of rated tripping currents

 

2  Type designation


 

3 Nominal operation conditions

1. Ambient operating temp. range-5~40℃;≤90%/20℃;50%/40

2. Operating altitude ≤2000m 

3. Mounting typeDin rail embedded(TH35-7.5).

4.Pollution degree:2

5.Overvoltage category:Ⅱ、Ⅲ

6.Terminal connection type:Cable

7.Torque : 2.5 N·m

4  Technical data

Specifications

Frame size current

100A

Rated operational voltage(Ue)

AC230V/2P、AC400V/4P

Rated insulation voltage(Ui)

AC400V

Rated current(In)

See Table 2

Rated impulse withstand voltage(Uimp)

4KV

Rated sensitivity(In)

See Table 2

Poles

2P、4P

Rated residual making &breaking capacity(Im)

1000A

Rated conditional short-circuit current(Ic)

3000A

Tripping time

<0.1s

Mechanical life

4000

Electrical life

2000

Protection degree

IP20

Compliant standard

GB/T 16916.1

Certification

CCC

 

Table 2

 Type

Rated current (In)/A

Sensitivity(In)/mA

S

1620253240506380

100300

A

16202532405063

1030100

AC

1620253240506380100

1030100300

5 Conductor requirements and cross-sectional area

Rated currentIn

Nominal cross-sectional area (mm2)

16A

2.5

25A

4

32A

6

40A

10

50-63A

16

80A

25

100A

35

 

 

 

 

6  Order specifications

 

When ordering circuit breakers, the following points should be specified:

a) Product models, such as LEL5;

b) The number of polar lines of circuit breakers, such as 2P;

c) The rated current of the circuit breaker, such as 63A;

d) Rated residual operating current, such as 100mA;

e) Instantaneous release type: S type

f) Order quantity, e.g. 100 sets

Order template:   100   LEL5    2P   S   63   100mA

7 Dimensions (unit:mm)





Send Inquiry to This Supplier

  • Title
  • From*
  • toYuanzhao Xu
  • Message*
  • Minimum Order Quantity*
  • Unit
  • Verification Code*

ok
x

Confirm
Cancel
x
Sign into your account
Member ID or Email
Join Free