AC Contactor
Member Details
- Product Details
- Company Profile
AC Contactor
WWW.VECAS.CN
Contactor Application
Motor control
Resistive load
Utilisation Category
AC-1
AC-3
Poles Description
3P
Power Pole Contact Composition
3 NO
[Ue] Rated Operational Voltage
Power circuit: <= 690 V AC 50/60 Hz
[Ie] Rated Operational Current
9A/12A/18A/25A/32A/40A/50A/65A/80A/95A
(at <60 °C) at <= 440 V AC AC-3 for power circuit
Motor Power kW
1.1-25 kW at 220...230 V AC 50/60 Hz
4-45 kW at 380...400 V
4-45 kW at 415 V
4-45 kW at 440 V
5.5-55 at 500 V
5.5-45 at 660...690 V
Control Circuit Type
AC at 50/60 Hz
[Uc] Control Circuit Voltage
380 V AC 50/60 Hz
Colour
Black
Auxiliary Contact Composition
1 NO
[Uimp] Rated Impulse Withstand Voltage
6 kV coil not connected to the power circuit conforming to IEC 60947
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947-4-1
Overvoltage Category
III
Irms Rated Making Capacity
60 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated Breaking Capacity
48 A at 440 V for power circuit conforming to IEC 60947
Average Impedance
2.5 mOhm - Ith 20 A 50 Hz for power circuit
Power Dissipation Per Pole
0.09 W AC-3
Control Circuit Voltage Limits
Operational: 0.85...1.1 Uc at 50/60 Hz (at <55 °C)
Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <55 °C)
Operating Time
12...22 ms on closing
4...19 ms on opening
Mechanical Durability
10000000 cycles
Maximum Operating Rate
1800 cyc/h 60 °C
Inrush Power in VA
95 VA 50 Hz cos phi 0.75 (at 20 °C)
95 VA 60 Hz cos phi 0.75 (at 20 °C)
Electrical Durability
1400000 cycles AC-3
Mounting Support
DIN rail
Plate
Connections - Terminals
Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Tightening Torque
Power circuit: 1.2 N.m
Control circuit: 1.5 N.m